Sign In | Join Free | My hardware-wholesale.com
China Ningbo Brando Hardware Co., Ltd logo
Ningbo Brando Hardware Co., Ltd
Focus on your demands Offer you best solution
Verified Supplier

10 Years

Home > Solenoid Valve Coil >

JOIL Type JICI JISI JIFI JIHI Series Pulse Jet Solenoid Valve Coil

Ningbo Brando Hardware Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

JOIL Type JICI JISI JIFI JIHI Series Pulse Jet Solenoid Valve Coil

  • 1
  • 2

Brand Name : BRANDO

Model Number : BB13237513

Certification : None

Place of Origin : Ningbo, China

MOQ : 200

Price : Negotiation

Payment Terms : T/T, PayPal, Western Union

Supply Ability : 200000 pcs per month

Delivery Time : Negotiation

Packaging Details : Inner Box, Carton, Pallet

Name : JOIL Replacement Solenoid Coil

Enameled Wire Material : Copper

Voltages : DC24V, AC220V

Power : 57Watt

Hole Diameter : 13.2mm

Coil Height : 38.8mm

Coil Width : 36.0mm

Insulation Class : F, H

Connector : DIN43650A

Application : JICI, JISI, JIFI, JIHI Series Diaphragm Pulse Valves

Contact Now

JOIL Type JICI JISI JIFI JIHI Series Pulse Jet Solenoid Valve Coil

Ths is a solenoid coil mounted on JOIL JICI JISI JIFI JIHI series diaphragm pulse valves, which is a coil of wire which wraps around a piston type of device. When a solenoid is energized, a magnetic field is created when current is applied and the piston (plunger) of the mechanism lifts off the port in the valve assembly- which results in the valve opening. When the power is shut off to the solenoid the electromagnetic field dissipates and the plunger assembly seats back down over the port and the valve shuts down.

The effective current should be measured in AC regime, and that current should be set as a target for DC regime as well. Some ways to achieve that target would be reducing the supply voltage or using a current-limiting resistor.

Using a coil rated for DC current with an AC power supply, imposes the risk of vibrations since DC solenoid valves might not contain a shading ring or a rectifier circuit. These vibrations might damage the solenoid by stressing the components over time, and they can contribute to noise levels in the room. This can be worked around by using an external full-wave rectifier circuit with a capacitive filter.

Another problem is that the effective current will be several times lower in this case, and the magnetic force generated by the coil might not be large enough to move the armature from its resting position. A solution would be to use a larger voltage so that the effective current matches the rated current of the solenoid.

YouTube video of JOIL Replacement Solenoid Coil For Pulse Valve:

Main dimension of Solenoid Coil For JOIL JICI JISI JIFI JIHI Valves:

JOIL Type JICI JISI JIFI JIHI Series Pulse Jet Solenoid Valve Coil

Product details of JOIL Type Diaphragm Pulse Valve Solenoid Coil:

JOIL Type JICI JISI JIFI JIHI Series Pulse Jet Solenoid Valve Coil

Technical parameters of QR CY123 N282 C53056N Goyen Type Solenoid Coils:

Model
BB13237513
Hole Size
13.2mm
Height
38.8mm
Width
36mm
Connector
DIN 43650A
Insulation Class
F, H
Normal Voltages
DC24V, AC220V
Power
57Watt
Application Examples
JICI40, JISI40, JIFI40, JISI50, JIFI50, JISI65,
JIFI65, JISI80, JIHI 80, JIHI 100 Pulse Valves


Tips: The related diaphragm repair kits and armature assembly are all supply.

Brando factory production video of solenoid valve coils:

Insulation & Heat Dissipation:
1. Class F is encapsulated Nylon coil. Class H is encapsulated Phenolic coil (types H1 and H2 are open wound (not encapsulated)).


2. Consider the environment (see IP ratings). If the environment is higher than the IP rating of the coil takes measures to protect (ie shelter from the rain or heavy hosing).


3. Note that the coil must still be able to vent the excess heat (do not lag or place coil in a sealed housing without ventilation. This will cause the coil to heat stress and fail).


4. Coils can tolerate higher than rated ambient temperatures when energized for short periods of time. This time varies depending on the coil wattage, ambient and media temperatures.


5. Use the Power Saving plug to reduce the operating heat in process coils (only available in 240v Ac and 24v DC) that are energised for long periods of time in high ambient temperature applications.


6. Other considerations are Power, Media temperature and AC ripple in DC power supplies (they should be regulated and smoothed DC supply). Also the valve elastomer selected for specific chemical and media applications must be taken into consideration if operating in a high ambient environment.


7. Another consideration type H1 and H2 coils are open wound (IP54) and have the ability to dissipate heat quicker than the encapsulated coils (IP65) even though they are all Class H rated. Their lower IP rating must be taken into account.


8. Coils used in Process Systems valves are designed and tested for continuous service 100% duty cycle (ED100%).


9. They all meet the IEC 216 thermal endurance specifications when factory tested. Specific field applications are outside of our control and the site engineer must test to suit the environment.

Focus on your demands, Offer you best solution:

√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing

Welcome to your any question and inquiry!


Product Tags:

JOIL Solenoid Valve Coil

      

JICI Solenoid Valve Coil

      

Joil Type Magnetic Coil

      
China JOIL Type JICI JISI JIFI JIHI Series Pulse Jet Solenoid Valve Coil wholesale

JOIL Type JICI JISI JIFI JIHI Series Pulse Jet Solenoid Valve Coil Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Brando Hardware Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)